Bienvenue à XIAMEN TOB NEW ENERGY TECHNOLOGY Co., LTD..
  • français
  • Russian
  • f
  • i
  • y
  • t
  • p
battery machine and materials solution
Produits

Produits chauds


Potentiostat multicanal
加载中...

Potentiostat multicanal Galvanostat EIS

Ce galvanostat potentiostat multicanal TOB-CS310X EIS est un instrument polyvalent offrant 8 emplacements.
  • Marque:

    TOB NEW ENERGY
  • article no.:

    TOB-CS310X
  • ordre (moq):

    1set
  • Paiement:

    L/C, T/T
  • origine du produit:

    China
  • port d'expédition:

    XIAMEN
Détails du produit

Potentiostat multicanal Galvanostat EIS


CARACTÉRISTIQUES


Ce galvanostat potentiostat multicanal TOB-CS310X EIS est un instrument polyvalent offrant 8 emplacements.

Le module entièrement flottant et la conception d'isolation électrique garantissent que chaque canal est totalement indépendant, ce qui garantit des données précises et des mesures simultanées efficaces.

Le potentiostat multicanal est pratique pour ceux qui disposent de nombreux échantillons et constitue un appareil idéal pour les études des matériaux énergétiques, l'étude des batteries, la corrosion des métaux, etc.

Le nombre de canaux peut être personnalisé. Différentes configurations vous garantissent d'obtenir le produit souhaité  adapté à différents budgets.


Potentiostat multicanal (±1A, ±10V)
Chaque canal est indépendant

Modèle : TOB-CS310X

Option A

4 canaux,
EIS * 1 canal

Option B

4 canaux,
EIS * 4

Option C

8 canaux,
EIS * 1

Option D

8 canaux,
EIS * 8

Le nombre de canaux est extensible en ajoutant et en installant davantage de cartes, grâce au châssis intelligent et à la conception enfichable. La plage de contrôle du potentiel de chaque canal est de 10 V, la plage de contrôle du courant ± 1 A, peut répondre aux exigences d'expérimentation de la plupart des gens.

Potentiostat multicanal


Application


● Etude des matériaux énergétiques (batterie Li-ion, cellule solaire, pile à combustible, supercapacités), matériaux fonctionnels avancés

● Électrosynthèse, galvanoplastie/électrodéposition, oxydation anodique, électrolyse

● Etude de corrosion et évaluation de la résistance à la corrosion des métaux ; évaluation rapide des inhibiteurs de corrosion, des revêtements et de l'efficacité de la protection cathodique

● Électrocatalyse (HER, OER, ORR, CO2RR, NRR)


Caractéristiques

Nombre de canaux : 4/ 8

Résistance d'isolation des canaux : > 100 MΩ

Communication : Ethernet

Filtre passe-bas : couvrant 8 décades

Plage de contrôle potentielle : ± 10 V

Plage de contrôle à courant constant : ± 1 A

Précision potentielle : 0,1 % × plage complète ± 1 mV

Précision actuelle : 0,1 % × plage complète

Résolution potentielle : 10 μV (> 100 Hz), 3 μ V (< 10 Hz)

Résolution actuelle : 1 pA

Temps de montée potentiel : ﹤1μs(<10mA),<10μs(<2A)

Plage de courant : 2nA ~ 1A, 10 gammes

Impédance d'entrée de l'électrode de référence : 1012Ω||20pF

Sortie de courant maximale : 1 A

Tension de conformité : ±21 V

Incrément de courant pendant le balayage : 1 mA à 1 A/ms

Taux de balayage CV et LSV : 0,001 mV ~ 10 000 V/s

Incrément potentiel pendant le balayage : 0,076 mV à 1 V/ms

Largeur d'impulsion CA et CC : 0,0001 ~ 65 000 s

Largeur d'impulsion DPV et NPV : 0,0001 ~ 1 000 s

Fréquence SWV : 0,001 ~ 100 KHz

Incrément de potentiel minimum CV : 0,075 mV

Acquisition de données AD : 16 bits à 1 MHz, 20 bits à 1 kHz

Fréquence IMP : 10 μHz ~ 1 MHz

Résolution DA : 16 bits, temps de configuration : 1 μs

Plage de courant et de potentiel : automatique

Exigences du système d'exploitation : 

Windows 7/8/10/11

Poids : 12,5 kg 

Dimensions: 40*40*14 cm    

Spectroscopie d'impédance électrochimique (EIS)

Générateur de signal

Gamme de fréquences EIS : 10 μHz ~ 1 MHz

Amplitude du signal CA : 1 mV ~ 2 500 mV

Précision de fréquence : 0,005 %

Résolution du signal : 0,1 mV RMS

Impédance de sortie DDS : 50 Ω

Biaisie CC : -10 V ~ + 10 V.

Distorsion des ondes : <1 %

Forme d'onde : onde sinusoïdale, onde triangulaire, onde carrée

Mode de numérisation : logarithmique/linéaire, augmentation/diminution

Analyseur de signaux

Maximum integral time:106cycles or 105s

Measurement delay:0~105S

Minimum integral time:10ms or the longest time of a cycle

DC offset compensation

Potential compensation range: -10V~+10V

Current compensation range: -1A~+1A

Bandwidth adjustment: automatic and manual, 8-decade frequency range


Advantages:

High current/voltage: Applied potential range ±10V, current ±1A. It can meet the needs of most studies.

Comprehensive techniques: Built-in EIS (10μHz~1MHz) is equipped. There are comprehensive techniques in each channel.

Warranty: 5 years warranty. We're the manufacturer, and our engineers will provide technical support anytime you need.

Low cost: The price includes instrument host, software (experiment control & data processing), necessary cables, dummy cell. No other charges. 

Reliability &quality: We've been in the market for 20 years, and now is the No. 1 brand of potentiostat product in China.


Techniques in each channel


Stable polarization Transient Polarization Chrono Method Amperometric
• Open Circuit Potential (OCP) • Multi Potential Steps • Chronopotentiometry (CP) • Differential Pulse Amperometry (DPA)
• Potentiostatic (I-T curve) • Multi Current Steps • Chronoamperametry (CA) • Double Differential Pulse Amperometry (DDPA)
• Galvanostatic • Potential Stair-Step (VSTEP) • Chronocaulometry (CC) • Triple Pulse Amperometry (TPA)
• Potentiodynamic (Tafel plot) • Galvanic Stair-Step (ISTEP) - • Integrated Pulse Amperometric Detection (IPAD)
• Galvanodynamic (DGP) - -


Battery test Corrosion Measurements Electrochemical Impedance Spectroscopy (EIS) Voltammetry
• Battery Charge and Discharge • Cyclic polarization curve (CPP) • Potentiostatic EIS (Nyquist, Bode) • Linear Sweep Voltammetry (LSV)
• Galvanostatic Charge and Discharge (GCD) • Linear polarization curve (LPR) • Galvanostatic EIS • Cylic Voltammetry (CV)
• Potentiostatic Charging and Discharging(PCD) • Electrochemical Potentiokinetic Reactivation (EPR) • Potentiostatic EIS (Optional freq.) • Staircase Voltammetry (SCV) #
• Potentiostatic Intermittent Titration Technique (PITT) • Electrochemical Noise (EN) • Galvanostatic EIS(Optional freq.) • Square Wave Voltammetry (SWV) #
• Galvanostatic Intermittent Titration Technique (GITT) • Zero resistance Ammeter (ZRA) • Mott-Schottky • Differential Pulse Voltammetry (DPV) #
- - • Potentiostatic EIS vs. Time (Single freq.) • Normal Pulse Voltammetry (NPV)#
- - • Galvanostatic EIS vs. Time (Single freq.) • Differential Normal Pulse Voltammetry (DNPV) #
- - - • AC Voltammetry (ACV)
- - - • 2nd harmonic AC Voltammetry (SHACV)
- - - • Fourier Transform AC Voltammetry (FTACV)
- - - #: there is corresponding stripping voltammetry


Simultaneous Measurements


You can run a same experiment for each channel at the same time. Set the same parameters for each experiment once and run all independently. It's especially useful when you have many samples for one single test.

Mesures simultanées

You can also choose different techniques in each channel. Set the parameters for each experiment one by one, and run each experiment independently. As is shown in right picture, EIS, Galvanostatic charge & discharge, Cyclic Voltammetry, and polarization curve test are tested.

différentes techniques dans chaque canal

Technical advantages


1. Impedance (EIS)

The potentiostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.).


2. Polarization curve

Tafel plot can be obtained. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to obtain material’s pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The softwa

re uses non-linear fitting to analyze polarization curve, and can make fast evaluation of material’s anti-corrosion ability and inhibitors.



EIS of AA6063 Al alloy in Ce3+ containing 3% NaCl solution
Polarization curve of Ti-based amorphous alloy & stainless steel in 3%NaCl solution


3. Voltammetry

Linear Sweep Voltammetry (LSV), Cyclic Voltammetry (CV), SCV, SWV, DPV, NPV, ACV, Stripping voltammetry etc. It integrates calculation of peak area, peak current and standard curve analysis.



LSV: mesoporous carbon material in 0.1M KOH
CV of PPy supercapacitor in 0.5 mol/L H2SO4


4 Electrochemical Noise

With high-resistance follower and zero-resistance ammeter, it measures the natural potential/current fluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.

5. Full floating measurement

Full-floating mode be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)


6. Software development kit (SDK)

  We are able to provide API functions and development examples, which facilitates some users’ requirements for secondary development and self-defined measurements. We can provide .dll file.


Software Features


Cyclic voltammetry: CS studio software provides users a versatile smoothing/differential/integrationkit, which can complete the calculation of peak height, peak area and peak potential of CV curves. In CV technique, during the data analysis, there is function of selecting exact cycle(s) to show.

Voltamétrie cyclique


Tafel plot and corrosion rate:

CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.

Tracé de Tafel et taux de corrosion

Test et analyse de la batterie :

efficacité de charge et de décharge, capacité, capacité spécifique, énergie de charge et de décharge.

Test et analyse de batterie


Analyse EIS : tracé de Bode, Nyquist et Mott-Schottky

Lors de l'analyse des données EIS, une fonction d'ajustement intégrée permet de dessiner le circuit équivalent personnalisé.

Analyse EIE


Sauvegarde des données en temps réel : les données peuvent être automatiquement enregistrées même en cas de mise hors tension soudaine.


Test combiné : il peut faciliter l’automatisation des expériences et gagner du temps. Grâce à la fonction unique de test combiné, vous pouvez choisir plusieurs techniques et définir le temps d'attente, l'heure de début et les cycles. Choisissez les expériences que vous souhaitez exécuter. Vous pouvez ensuite effectuer des mesures automatiques des expériences définies comme vous le souhaitez sans avoir à attendre au laboratoire. Cette fonction est particulièrement utile si vous avez plusieurs expériences à exécuter et vous fait gagner beaucoup de temps.

Test combiné


Ouverture des données : vous pouvez ouvrir les fichiers de données au format txt dans le bloc-notes. Les données peuvent également être ouvertes dans Origin

Fourniture standard


1 Hôte d'instrument TOB-CS310X  1 jeu
2 Logiciel de test et d'analyse CS Studio 1 jeu
3 Câble d'alimentation 1 pièce 1 pièce
4 Câble Ethernet 1 pièce 1 pièce
5 Câble cellulaire  8 (Options A et B)  16 (Option C&D) pièces
6 Cellule factice  4(Options A et B)  8 pièces (Option C&D)
7 Service  Tout le service, la réparation est totalement gratuite
8 Période de garantie 5 années
9 Fournir un guide d'installation, un manuel, une vidéo d'installation du logiciel et des vidéos de formation
dix Service de réparation gratuit
11 Mise à niveau logicielle et service technique à vie


Il s'agit du  poste de travail électrochimique à canal unique , cliquez pour plus d'informations



Courriel :  tob.amy@tobmachine.com

Skype: amywangbest86

Whatsapp/Numéro de téléphone : +86 181 2071 5609

envoyer un message

si vous êtes intéressé par nos produits et souhaitez en savoir plus, laissez un message ici, nous vous répondrons dans les plus brefs délais.

nos oeuvres
Produits connexes
Poste de travail électrochimique
Poste de travail électrochimique à canal unique potentiostat Galvanostat Pour le test de la batterie
Le poste de travail électrochimique est un agent général potentiostat Galvanostat FRA Conçu pour l'électrochimie générale Mesures.
Poste de travail électrochimique
Potentiostat multicanal Galvanostat Poste de travail électrochimique
Le potentiostat/galvanostat/EIS multicanal TOB-CS-3 est un instrument polyvalent offrant 8 emplacements. Courant/tension élevé : plage de potentiel appliquée ±10 V, courant ±1 A. Techniques complètes : EIS intégré (10 μHz ~ 1 MHz) est équipé.
Bipotentiostat
Bipotentiostat 2 canaux
Le bipotentiostat TOB-CS-2350 est développé à partir du potentiostat/galvanostat TOB-CS-350 à canal unique. Il existe deux ensembles de potentiostat/galvanostat intégrés. Les deux canaux peuvent mener des expériences identiques ou différentes, indépendamment/simultanément.
Machine d'enroulement de cellules cylindriques
Machine de découpe et d'enroulement au laser pour cellule cylindrique
La bobineuse de batterie est utilisée pour le bobinage de précision de batterie de cylindre au lithium pour la chaîne de production. Convient pour 18650 21700 26650 32700 et autres batteries cylindriques
Machine de revêtement micro-concave
Machine de revêtement micro-concave de précision pour séparateur de batterie
Cette machine de revêtement de séparateur de batterie TOB-W400-2.4 est utilisée pour le revêtement de précision des séparateurs de batterie lithium-ion.
Poudre de ferrate de manganèse sodique
Poudre de ferrate de manganèse sodique pour matériaux de cathode de batterie ionique sodium
TOB New Energy fournit des matériaux de cathode en poudre de ferrate de sodium et de manganèse en tant que matériaux de cathode de batterie aux ions sodium.
Trois électrodes
Cellule de test de batterie à trois électrodes en titane de haute pureté
Cette cellule de test de batterie à trois électrodes TOB-SL3E2-14 est utilisée pour les batteries à base d'eau, les batteries au zinc ou les environnements hautement corrosifs. Son diamètre intérieur est de 14 mm (peut être personnalisé).
ncm811 poudre
linicomno2 (ni: co: mn = 8: 1: 1) ncm poudre pour batterie li-ion
lithium nickel manganèse oxyde de cobalt nmc 811 matériau cathodique poudre.

laisser un message

    si vous êtes intéressé par nos produits et souhaitez en savoir plus, laissez un message ici, nous vous répondrons dans les plus brefs délais.

Accueil

Produits

entreprise

Haut